Improved Durability with top quality manufactured insulation ensuring full compliance with industry standards, designed to withstand extreme temperatures, moisture and physical harms
RRH Cable we have the capability to manufacture grade A 99.9% pure copper precisely stranded in the insulators for the best conductivity and efficiency
Thanks to our expert craftsmanship, we provide high-quality cables that minimize the need for frequent maintenance or replacements, significantly reducing long-term operational costs.
Cable Type | AWG Size | mm² | Voltage Rating | Ampacity | Insulation Type | Conductor Material | Core Type | No. of Conductors | Operating Temperature |
FR PVC Power Cable | 10 – 22 AWG | 0.34 – 5.3 | 300V / 600V | 3 – 30 A | FR PVC | Stranded Copper | Single or Multicore | 1 – 4C / 3C+E | –10°C to +70°C |
FRLS Power Cable | 14 – 4 AWG | 2.5 – 25 | 600V – 1kV | 15 – 60 A | FRLS (Low Smoke PVC) | Stranded Copper | Multicore | 2 – 5 | –15°C to +85°C |
LSZH Instrumentation Cable | 16 – 22 AWG | 0.5 – 1.5 | 300V – 600V | 2 – 5 A | XLPE / LSZH | Tinned Copper | Pairs / Triads | 1 – 24 Pairs | –20°C to +90°C |
Control Cable (FR) | 12 – 22 AWG | 0.34 – 4.0 | 300V – 1000V | 4 – 30 A | XLPE / PVC / LSZH | Bare/Tinned Copper | Multicore | 2 – 61C | –25°C to +90°C |
Halogen-Free Data Cable | 24 – 20 AWG | 0.20 – 0.52 | 48V (PoE) / 300V | ~0.5 – 5 A | LSZH | Solid / Stranded Copper | Twisted Pair | 4 pairs (Cat5e/6) | –20°C to +75°C |
Armored FRLS Cable | 14 – 4 AWG | 2.5 – 25 | 600V – 1.1kV | 15 – 60 A | FRLS / XLPE | Stranded Copper | Multicore | 2 – 4C or 3.5C | –25°C to +90°C |
Fire Alarm Cable | 18 – 16 AWG | 0.75 – 1.5 | 300V – 600V | 2 – 5 A | FR PVC / LSZH | Stranded Tinned Copper | Twisted Pair / Shielded | 1 – 4 Pairs | –15°C to +70°C |
Elevator/Building Cable | 16 – 10 AWG | 1.0 – 6.0 | 300V – 600V | 5 – 35 A | LSZH / FRLSH | Stranded Copper | Flat / Round | 2 – 24C | –20°C to +90°C |
FR (Flame Retardant): Stops flame from propagating on the cable surface
FRLS (Flame Retardant Low Smoke): Emits less smoke than standard FR
LSZH (Low Smoke Zero Halogen): Minimal toxic and corrosive gas emissions
XLPE (Cross-linked Polyethylene): High thermal resistance, used in FR applications
Multicore: Multiple conductors under one outer sheath, common in control cables
Triads/Pairs: Used in instrumentation and signal cables for noise reduction
Commercial Buildings Power and communication cabling in offices, malls, hospitals, etc.
Industrial Facilities Motor, control, and signal cables in factories or process plants
Mass Transit Systems Subways, trains, and buses require fire-safe wiring for public safety
Oil & Gas / Petrochemical Flame-resistant wiring in explosive or fire-risk zones
Power Plants & Utilities Cable trays, control rooms, and underground pathways
Marine & Offshore Shipboard cable systems where fire safety is critical
Data Centers Safe data/power cabling with low-smoke, halogen-free options
Airports & Stadiums Public venue installations with strict fire codes
Tunnels & Underground Systems Ventilation, lighting, and signaling cable networks with fire-retardant specifications
Apply cable base on its insulation property
Always de-energize the system before working on cables
Proper PPE duing operation
Feature | Why It Matters |
Self-extinguishing | Limits flame spread and potential damage |
Low Smoke Emission | Improves visibility and reduces inhalation risk during evacuation |
Low/Zero Halogen Emission | Prevents release of corrosive gases that harm electronics and humans |
Compliant with Fire Standards | Required by international building and safety codes (IEC, UL, BS, EN standards) |